China Manufacture 12 Channel Ecg Machine With Torely 12 Lead Resting Ecg Machine MSLEC32
Product Specification :

Product Features:
Overview Standard/Cabrera 12-Leads 7" LCD Color Screen Simultaneously 12-Leads Acquisition Manual/auto 3CH, 3CH+1R, 3CH+2R, 6CH, 6CH+1R display Manual/auto 6-Channels Simultaneously- Printing (without distortion) Electrode Disconnection Alarm (Diagram) Automatic measurement & analysis 5minutes arrhythmia analysis Security type: |type CF
Technique Specification | Physical Specification | Grounding Wire | ||
Dimension & weight | User Manual | |||
Equipment: | Paper Axis | |||
270mm×270mm×75mm; 2.5kg | ||||
Package: | Optional Accessories | |||
375mm×365mm×230mm; 4.5kg | Series Electrodes | |||
Monitor | Thermal Printing Paper | |||
Sampling rate: | 8000Hz (1ms) | 7" High-resolution Color LCD Screen | SD Memory Card | |
Frequency Response: | 0.05 ~ 150Hz (-3dB) | Electrical Power | Lithium Battery | |
AC: 220V±10%, 50Hz/60Hz DC: Built-in rechargeable battery | Workstation Software | |||
Time Constant: | ≥ 3.2s | Workstation Trolley | ||
CMRR: | > 100dB | Data Storage: Max. 500 sets | Laser/Inkjet Printer | |
Patient Leakage Current: | <10µA | Environmental Conditions | Paper Axis | |
Input Mode: | floating input | Transportation Temperature:-20ºC~+50ºC | ||
Input Circuit: | < 50μA | Relative Humidity:10%~95% | Certificates | |
Noise Level: | ≤ 15μVp∽p | Atmospheric Pressure:700hPa~1060hPa | Quality Standards | |
Sensitivity valve: | 20 μV | Storage Temperature:-20ºC~+50ºC | ISO9001 | |
Polarization Voltage: | ±600mV | Relative Humidity:10%~95% | ISO13485 | |
Calibration Voltage: | 1mV ±2% | Atmospheric Pressure:700hPa~1060hPa | CMD | |
Continuous Operating: | AC ≥ 10h & DC ≥ 3h | Operation Temperature:5ºC~+40ºC | CCC | |
Relative Humidity:25%~80% | Design Standards | |||
A/D shift: | ≥ 20 | Atmospheric Pressure:700hPa~1060hPa | EN60601-1 & EN60601-1-2 | |
Input Impedance: | ≥ 50 MΩ | EN60601-2-25 & EN60601-2-51 | ||
Sensitivity: | 1.25, 2.5, 5, 10, 20, 40 mm/mV±2% | System Inputs & Outputs | EN60601-1-4 & EN62304 | |
RS-232/ USB2.0/ RJ-45/ SD Interface | EN ISO13485 & EN ISO10993-1 | |||
(6levels/automatic adjustment) | Audio Output Interface | CE Declaration | ||
Paper Speed: 5, 6.25, 10, 12.5, 25, 50mm/s ±3% (6 levels adjustment) | MSLEC32 has been assessed with respect to | |||
Standard Package | the conformity assessment procedure | |||
Recording Mode: | Thermal array printer | MSLEC32 ECG Machine (with battery) | described in Article 11.3.a and Annex II | |
8 dot/ mm (Vertical) 40 dot/ mm (Horizontal, 25mm/s) | Patient Cable | excluding section 4 (Module H) of Council | ||
Chest Electrodes | Directive 93/42/EEC on Medical Devices, | |||
Paper Size: | Limb Electrodes | as amended, and found to comply. | ||